A SECTION OF ROOF MEASURING APPROX. 19'X25'X6' FELL IN THE INTERSECTION OF #4 ENTRY AT SS 1396, INTERSECTON HAD A CUTTER RUNNING THROUGH WITH SOAPSTONE AND WATER DRIPPING FROM ROOF AREA WAS BO LTED WITH 3' FULLY GROUTED RESIN BOLTS AND ROOF MATS ON AT LEAST 1 3'X4' PATTERN ROCK FELL ON MINER AND #1 BRIDGE.