# FALL OF ROOF OR BACK
> MSHA accident `220020500022` · 02/11/2002 · Solar Sources Underground L L C
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Felson  Bowman
- **Operator:** Solar Sources Underground L L C
- **Mine:** [1202103](https://api.ai-analytics.org/mine/1202103)
## Narrative

AN UNINTENTIONAL ROOF FALL OCCURRED IN THE #1 ENTRY, INBY THE LAST OPEN CROSS CUT, IN THE 001 WORKING SECTION. THE ROOF FALL WAS 42'LONG,18 & 1/2'WIDE AND 6'HIGH. THE ROOF FALL WAS CLEANED UP AND THE AREA WAS RE-SUPPORTED WITH 6'FULLY GROUTED ROOF BOLTS AND INDICATED NO ADVERSE ROOFCONDITIONS. THE ROOF MATERIAL CONSISTED OF FINELY LAMINATED SANDY DARK GRAY SHALE.

---