← MSHA accidents

FALL OF ROOF OR BACK

220020670037 · 03/01/2002 · McCoy Elkhorn Coal Corp

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
James River Coal Company
Operator
McCoy Elkhorn Coal Corp
Mine
1518085

Narrative

ROOF FALL OCCURED IN #5 ENTRY 1 BREAK INBY SURVEY STATION 15313. THE FALL WAS APPROX 20' LONG X 20' WIDE X 6' THICK. THE ORIGINAL ROOF SUPPORT IN THE AREA WAS 4' RESIN GROUTED RODS. (THIS ENTR Y WAS BELT ENTRY.)

Source

Authoritative
MSHA Open Government Data
Machine