A SECTION OF ROOF 30' LONG X 6-8' THICK, RIB TO RIB, FELL, 2 BRKS OUTBY SPAD #787 IN #4 ENTRY MEUTRAL ABOUT 600' FROM SECTION. AREA WAS SUPPORTED WITH 6' FULLY GROUTED BOLTS. AREA WAS DEVELOPE D 2-8-02. ROOF WAS LAMINATED SHALE & SANDSTONE, NO WATER OR RIDER SEAM PRESENT.