ROOF FALL IN NEW EAGLE, RIVER HEADINGS SECTION #1 ENTRY AT 11+70'. FALL IS 1/2 INTERSECTION DIAGNALLY AND @ 2.5'INTO CROSSCUT. FALL IS UP TO 42FT.LONG, 17'WIDE, UP TO 11'HIGH. A CLAY VEIN RAN DIAGNALLY THRU THIS INTERSECTION. AREA WAS MINEDWEEK OF 3-3-02 WITH CONTINUOUS MINER AND SUPPORTED WITH 7FT. POINT ANCHOR ROOF BOLTS.