# ELECTRICAL
> **FATAL** · MSHA accident `220021540017` · 05/23/2002 · Calvary Coal Co. Inc
## Details
- **Degree of injury:** FATALITY
- **Classification:** ELECTRICAL
- **Accident type:** Contact with electrical current
- **Occupation:** Electrician, Lineman
- **Activity:** Electrical maintenance
- **Injury source:** ELECTRICAL APPARATUS,NEC
- **Nature of injury:** ELECTRIC BURN-CNTACT BURN
- **Body part:** MULTIPLE PARTS (MORE THAN ONE MAJOR)
- **Days lost:** —
- **Mine experience:** 5.38 years
## Operator
- **Controller:** Charles  Collins
- **Operator:** Calvary Coal Co. Inc
- **Mine:** [1516349](https://api.ai-analytics.org/mine/1516349)
## Narrative

THE ELECTRICIAN WAS WORKING ON A GROUNDED SHUTTLE CAR CABLE AND RECEIVED FLASH BURNS WHEN A SHORT CIRCUIT OCCURED AT THE FEMALE RECEPLACLE ON THE ELECTRICAL POWER CENTER.

---