ROOF FALL IN THE NEW EAGLE 3 MAIN AREA FROM 49- 50 CROSSCUT IN THE 000 ENTRY. FALL IS APPROX. 18'WIDE, 20'LONG, 7'HIGH. AREA HAD A CLAY VEIN RUNNING ACROSS ENTRY. AREA WAS MINED @7-01 WITH CONTINUOUS MINER AND SUPPORTED WITH 7'POINT ANCHOR ROOF BOLTS.