AN UNINTENTIONAL ROOF FALL OCCURRED ON THE #1 SECTION IN THE 4 TO 3 CROSSCUT, 2 BREAKS INBY SPAD #12381 APPROX. 750' OUTBY THE WORKING FACE. THE FALL MEASURED 100'L X 20'W X 6'H. ALL ENTRANCES TO THE FALL HAVE BEEN BREAKERED OFF. THIS AREA WILL NOT BE REHABILITATED.