# HOISTING
> MSHA accident `220022130010` · 07/22/2002 · The Doe Run Company
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** HOISTING
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Renco Group
- **Operator:** The Doe Run Company
- **Mine:** [2300409](https://api.ai-analytics.org/mine/2300409)
## Narrative

MAINTENANCE WAS DOING WEEKLY INSPECTION OF BRAKE WEAR LIMIT SWITCH AND UNIT WOULDN'T RESET. ELECTRICIANS WERE CALLED AT 2:40 P.M. AND THEY CHECKED CIRCUITS UNTIL THEY FOUND THE RELAY CONTACT C OIL ON UVM TO MAIN CONTACTOR WAS BURNED AND HAD TO BE REPLACED. WORK WAS COMPLETED AT 6:05 P.M. SAME DAY AND MSHA WAS CALLED AND TOLD HOIST WAS BACK IN SERVICE.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*