A ROOF FALL OCCURRED MEASURING 16'X20'X5' IN THE RIGHT WORKING SECTION IN #1 ENTRY FACE. THIS AREA HAD APPROXIMATELY 100 FT OF COVER & APPEARS TO HAVE SOME HORIZONTAL STRESS. NO EQUIPMENT WAS INVOLVED. NO VENTILATION WAS DISTURBED. NO INJURY OCCURRED & THE FALL WILL NOT BE CLEANED UP.