AN UNPLANNED ROOF FALL OCCURRED ON THE 2 LEFT OFF 3 EAST SECTION, #3 ENTRY BETWEEN SURVEY STATIONS #2833 & #2859. THE FALL MEASURED 120' LONG, 18' WIDE & 6' THICK. THE AREA HAD BEEN SUPPORTED WITH 4' RESIN ROOF BOLTS. THE FALL HAS BEEN TIMBERED OFF & WILL NOT BE CLEANED UP.