AN UNINTENTIONAL ROOF FALL OCCURED IN THE RT. SIDE ROOMS APPROX. 100 FT FROM SURVEY STATION 43381 & 43292. THE FALL FELL FROM FACE OF THE #4 RM. THRU CROSSCUT INTO FARE OF #3 RM. FALL MEASURED APPROX. 70'LX18'WX6' HIGH. ADVERSE CONDITIONS WERE BEING ENCOUNTERED DUE TO ONLY APPROX. 100' OF COVER AND WITHIN 150' OF OUTCROP. FALL WILL NOT BE CLEANED UP.