← MSHA accidents

FALL OF ROOF OR BACK

220022600042 · 09/06/2002 · Blue Mountain Energy Inc

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
Deseret Generation & Transmission Co-operative
Operator
Blue Mountain Energy Inc
Mine
0503505

Narrative

ON FRIDAY SEPTEMBER 6TH AT 3:45 PM, THE FIRE BOSS FOUND A ROOF FALL BETWEEN NO.52 AND NO.53 CROSSCUT IN THE 3 LEFT WEST RETURN. THE FALL WAS APPROXIMATELY 45 FEET LONG, 17 FEET WIDE AND 8 FT T O 9 FT HIGH. THE AREA HAD MUD STONE, SHALES AND COAL TOP WHICH CONTRIBUTED TO THE FALL IN THIS AREA. NO EVIDENCE OF FAILURE WAS OBSERVED IN THIS AREA PROIR TO THE ROOF FALL.

Source

Authoritative
MSHA Open Government Data
Machine