# FALL OF ROOF OR BACK
> MSHA accident `220022600077` · 09/10/2002 · Solar Sources Underground L L C
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Felson  Bowman
- **Operator:** Solar Sources Underground L L C
- **Mine:** [1202103](https://api.ai-analytics.org/mine/1202103)
## Narrative

AN UNINTENTIONAL ROOF FALL OCCURRED IN THE #5 ENTRY BETWEEN #24 AND #25 CROSSCUTS. THIS WAS LOCATED ALONG THE CONVEYOR BELT ENTRY OF THE 5S/2E WORKING SECTION. THE ROOF FALL WAS 57'LONG, 18' WIDE & 5'HIGH. THE ROOF FALL WILL BE CLEANED UP & THE AREA WILL BE RE-SUPPORTED. INITIALLY THE AREA WAS BOLTED WITH 4' FULLY GROUTED ROOF BOLTS AND SHOWED NO INDICATION OF FAILURE. GRAY SHALE.

---