A ROOF FALL OCCURRED AT 2000 ON 1-8-02. LOCATED IN FOUR WAY INTERSECTION AT 5+60 ENTRY 5 OUTBY LOADING POINT 5LMS SECTION. AREA HAD BEEN MINER 9-9-02 AND WAS BOLTED WITH 5' RESIN BOLTS. FALL M EASURED 20' X 70' X 10'. NO INJURY RESULTED BUT AN INTAKE STOPPING WAS LOST.