A ROOF FALL OCCURED INT HE #2 ENTRY INBY #59 CROSSCUT ON THE 003 PILLAR SECTION AND FELL APPROX. 6' HIGH X 18' WIDE X 40' LONG CATCHING TWO MOBILE ROOF SUPPORTS AND THE HEAD OF THE CONTINUOUS MINER. THE AREA HAD BEEN BOLTED WITH 5' TORQUE TTENSION BOLTS, AND TIMBERS HAD BEEN SET AS SUPPLEMENTARY SUPPORT.