← MSHA accidents

FALL OF ROOF OR BACK

220023160151 · 11/04/2002 · Solar Sources Underground L L C

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
Felson Bowman
Operator
Solar Sources Underground L L C
Mine
1202103

Narrative

AN UNINTENTIONAL ROOF FALL OCCURRED IN THE #7 ENTRY AT THE #20 CROSSCUT. THIS WAS LOCATED ALONG THE MAIN NORTH INTAKE. THE ROOF FALL WAS 30'LONG, 17'WIDE & 5'HIGH. THE FALL WILL BE CLEANED UP & THE AREA WILL BE RE-SUPPORTED. INITIALLY THE AREA WAS BOLTED WITH 4'FULLY GROUTED ROOF BOLTS & SHOWED NO INDICATION OF ROOF FAILURE. THE ROOF MATERIAL CONSISTED OF SANDY GRAY SHALE.

Source

Authoritative
MSHA Open Government Data
Machine