# FALL OF ROOF OR BACK
> MSHA accident `220023220042` · 11/11/2002 · Genesis Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** John P  Garcia
- **Operator:** Genesis Inc
- **Mine:** [3608980](https://api.ai-analytics.org/mine/3608980)
## Narrative

A FALL OCCURRED PRIOR TO GETTING A CUT THROUGH BOLTED FROM #4 TO #5 ENTRY AT 9 AND 60. THE ROOFIN THE #5 ENTRY HAD BEEN BOLTED WITH 4' BOLTS AND METAL STRAPS (SKINS) THE ROOF STARTED WORKING AND SOME RE-BOLTING WAS STARTED IN THE X-CUT. THE FALL WENT 75' THROUGH THE CROSSCUT ACROSS #4 ENTRY AND 25' TOWARDS #3 ENTRY.

---