A ROOF FALL OCCURRED AT 0730 ON 11-11-02, AT 6+00 ENTRY 3 5RMS (MMU 007). THE FALL WAS IN A FOUR WAY INTERSECTION THAT WAS MINED ON 11-07-02. THE AREA HAD BEEN SUPPORTED WITH 8' RESIN BOLTS. N O INJURED SOME MINER CABLE WAS LOST. THE AREA WILL BE CLEANED UP AND RESUPPORTED.