ROOF FALL OCCURED IN THE #6 ENTRY (TRACK ENTRY) OF THE 003-004 SECTION. THE FALL WAS + 60'LONG, 19'WIDE, AND 6'THICK. THE FALL WAS 1 BREAK INBY SURVEY STATION NO. 16108. THE FALL WAS APPROX. 2800' OUTBY SECTION. IT WAS FOUND BY SECTION FOREMAN, DURING HIS PRE-SHIFT EXAM.