A ROOF FALL OCCURRED FOLLOWING PILLAR EXTRACTION. ONE MRS WAS LOWERED AND THE ROOF STARTED WORKING. IT WAS RESET WHEN A FALL STARTED INBY THE MRS AND IT CONTINUED OUTBY TO THE CROSSCUT. THE FA LL MEASURED APPROXIMATELY 100 FT LONG, 18 FEET WIDE AND 10-15 FT HIGH.