# FALL OF ROOF OR BACK
> MSHA accident `220030710048` · 03/07/2003 · American Energy Corporation
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Robert E  Murray
- **Operator:** American Energy Corporation
- **Mine:** [3301070](https://api.ai-analytics.org/mine/3301070)
## Narrative

A ROOF FALL WAS FOUND IN THE #2 ENTRY OF THE OLD 1 WEST MAINS AIRCOURSE OUTBY MP 2 STATION. THE FALL IS APPROXIMATELY 25' LONG BY 25' WIDE AND 8' HIGH. AREA WAS REBOLTED WITH 8' INSTALL II RE SIN ASSISTED ROOF BOLTS WITH SCREENS & HEADERS. FALL CAUSED BY BROKEN ROOF ABOVE THE BOLT ANCHORAGE. VENTILATION NOT AFFECTED BY IT DID AFFECT PRIMARY ESCAPEWAYS. WORK STARTED TO SUPPORT FALL.

---