# FALL OF ROOF OR BACK
> MSHA accident `220030730045` · 03/11/2003 ·  Clean Energy Mining Co.
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Massey Energy Company
- **Operator:**  Clean Energy Mining Co.
- **Mine:** [1510753](https://api.ai-analytics.org/mine/1510753)
## Narrative

A ROOF FALL OCCURED IN ONE OF THE RETURN ENTRIES 7000' FROM THE ACTIVE FACE. THE LOCATION WAS 100' INBY SURVEY STATION 3925. THE FALL MEASURED 100' IN LENGTH 20' WIDE AND 6' HIGH. THE AREA WAS BOLTED WITH 4' RESIN BOLTS.

---