AN UNPLANNED ROOF FALL OCCURRED IN #3 ENTRY (BELTLINE), 4 X-CUTS INBY MINE OPENING. FALL APPROX. 40' LONG, 19' WIDE, 14' HIGH. FALL WAS CLEANED UP TO RESTORE BELTINE. AREA WAS ROOF BOLTED WITH 36"" FULLY GROUTED RESIN BOLTS ACCORDING TO THE APPROVED ROOF CONTROL PLAN.