# FALL OF ROOF OR BACK
> MSHA accident `220031210063` · 04/28/2003 · Anker West Virginia Mining Company Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Anker Group Inc
- **Operator:** Anker West Virginia Mining Company Inc
- **Mine:** [4608622](https://api.ai-analytics.org/mine/4608622)
## Narrative

AN UNINTENTIONAL ROOF FALL OCCURRED IN E MAINS NO. 5 ENTRY AT SPAD 8464. THE FALL MEASURED 18FTWIDE X 72 FT. LONG X 14FT HIGH. THIS AREA WAS SUPPORTED WITH 5FT TORQUE TENSION BOLTS (FULLY GRO UTED) 14 FT CABLE BOLTS AND CRIBS UP EACH SIDE OF THE ENTRY WITH 5""X7X16' LONG WOODEN CROSSBARSON 4 FT CENTERS BOLTED TO THE MINE ROOF SUPPORTED BY THE CRIBS.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*