AN UNINTENTIONAL ROOF FALL OCCURRED IN 6-NORTH SECTION (REHABILITATION AREA) IN #8 ENTRY, 3 BLOCKS OUTBY THE FACE AREA, AT STATION SPAD #8332. IT FELL JUST ABOVE THE 5' RESIN ROOF BOLTS. THE L ENGTH OF THE FALL IS 18', AND WIDTH IS 9'. VENTILATION WAS NOT AFFECTED. 6-17-03 - ADDITIONAL MATERIAL FELL FOR 20' ADDITIONAL INBY.