← MSHA accidents

FALL OF ROOF OR BACK

220031740012 · 06/16/2003 · Consolidation Coal Company

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
CONSOL Energy Inc
Operator
Consolidation Coal Company
Mine
4601968

Narrative

AN UNINTENTIONAL ROOF FALL OCCURRED IN 6-NORTH SECTION (REHABILITATION AREA) IN #8 ENTRY, 3 BLOCKS OUTBY THE FACE AREA, AT STATION SPAD #8332. IT FELL JUST ABOVE THE 5' RESIN ROOF BOLTS. THE L ENGTH OF THE FALL IS 18', AND WIDTH IS 9'. VENTILATION WAS NOT AFFECTED. 6-17-03 - ADDITIONAL MATERIAL FELL FOR 20' ADDITIONAL INBY.

Source

Authoritative
MSHA Open Government Data
Machine