# FALL OF ROOF OR BACK
> MSHA accident `220031990039` · 07/15/2003 · Long Branch Energy
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Long Branch Energy Corporation
- **Operator:** Long Branch Energy
- **Mine:** [4608855](https://api.ai-analytics.org/mine/4608855)
## Narrative

THE FALL MEASURING 20' BY 30' BY 6-7' AND WAS IN 4 WAY INTERSECTION WITH WATER SEEPING THROUGH A SHALE IMMEDIATE ROOF. THE AREA WAS BOLTED WITH 48"" LONG ROOF BOLTS WITH 8"" BY 8"" BY 1"" HOLE PLATES. THE ENTRY IA A NEUTRAL ENTRY. THERE WAS NO DAMAGE TO ANY EQUIPMENT OR PERSONS.

---