DURING A WEEKLY INSPECTION OF THE INTAKE AIR COURSE A ROOF FALL WAS FOUND IN THE #7 ENTRY ADJACENT FROM SURVEY POINT 2243 ON THE 001-0 SECTION. THE FALL MEASURED 6' BY 80' BY 19'. VENTILATION WAS INTERRUPTED BUT STOPPINGS WERE MOVED TO OPENTHE PRIMARY ESCAPEWAY.