ON 7-15-03 A FALL WAS DISCOVERED ON #1 SECTION, BRK #33 @ SPAD 210. THE FALL MEASURED 40' LENGTH, 20' WIDTH AND 6' THICK. THE FALL WAS IN A NEUTRAL ENTRY. 6' RESIN BOLTS WERE TYPE OF ROOF SUPP ORT USED IN AREA. THE AREA WAS POSTED, TIMBERED OFF. NON-PRODUCING STATUS.