← MSHA accidents

HOISTING

220032230083 · 08/07/2003 · U S Gypsum Company

Details

Degree of injury
ACCIDENT ONLY
Classification
HOISTING
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
Mine experience
— years

Operator

Controller (parent)
USG Corporation
Operator
U S Gypsum Company
Mine
1200427

Narrative

THE HOIST LOST POWER AND THE MINE WAS EVACUATED. THE POWER OUTAGE WAS DUE TO AN ELECTRICAL PROBLEM IN THE HOIST MOTOR CONTROLS. THE CHIEF ELECTRICIAN WAS CALLED THE NEXT MORNING TO ASSESS THE SITUATION. THE ABB COMPANY WAS ALSO CONTACTED. THE ELECTRICAIN REPLACED A FUSE AND THE HOIST POWER CAME BACK ON AND IT STARTED RIGHT UP.