AN UNINTENTIONAL ROOF FALL WAS FOUND INT HE INTAKE ENTRY #7 APPROX. 300 FT OUTBY THE WORKING SECTION.T HE FALL OCCURRED DUE TO LAMINATED SLATE INTERMIXED WITH COAL STREAKS AVOE THE 4' RESIN RO OF BOLTS. THE FALL MEASURED 30' LONG X 18' WIDE X 6' TO 6.5' HIGH. THE FALL WAS ABOVE ANCHORAGE AND DID NOT AFFECT VENTIOLATION. PASSAGE OF MEN WAS NOT AFFECTED. NO INJURIES RESULT FROM THE F