# FALL OF ROOF OR BACK
> MSHA accident `220032610045` · 09/13/2003 · 3-D Management Services, Inc.
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Wendell R  Bias
- **Operator:** 3-D Management Services, Inc.
- **Mine:** [4608835](https://api.ai-analytics.org/mine/4608835)
## Narrative

AN AREA OF ROOF FALL FELL IN THE #8 ENTRY INTAKE AT SPAD #803 (OUTBY) AREA WAS DEVELOPED IN 3-5-02. AREA WAS BOLTED WITH 4' X 6' FULLY GROUTED BOLTS. ROOF WAS WET LAMINATED SLATE. FALL IS 50' LONG, 18' WIDE, 3 TO 5 FT THICK. FALL WILL NOT BE MOVED. STOPPING LINE WILL BE MOVED OVER ESTABLISHING ESCAPEWAY.

---