A ROOF FALL WAS FOUND ON 10/05/03 AT SURVEY STATION 11+40 ENTRY 6 5RMS MMU #007. THE FALL MEASURED 30'WIDE, 70'LONG & 12-15'HIGH. THE FALL WAS IN A 4 WAY INTERSECTION THAT HAD BEEN MINED ON 9/30/03. AREA HAD BEEN BOLTED WITH 8'FULL RESIN PINS. NO INJURY RESULTED APPROX. 500'OF MINER CABLE WAS LOST. THERE ARE NO PLANS TO CLEAN UP THE FALL.