AN AREA OF SUBNORMAL ROOF FELL AT AN INTERSECTION JUST INBY STATION #1227 IN #5 ENTRY OF 1 LEFT ROOM 5TH PANEL. THE FALL WAS 5 1/2 FEET TO 6 1/2 FT HIGH AND FROM RIB TO RIB IN THE INTERSECTION .T HE AREA WAS SUPPORTED WITH 48"" AND 72"" RESIN BOLTS WITH BACON SKINS.