FALL WAS FOUND DURING WEEKLY EXAM OF AIRWAYS, THIS AREA WAS DEVELOPED 1/31/02 & CONSISTS OF WEATHERED SHALE & STACK SHALE WITH SOME SLICK BACKS & FORMATIONS, SHALE WEATHERED AWAY JUST ABOVE ROOF BOLT ANCHORAGE ALLOWING ROOF TO FALL, NO PLANS TO REHAB. THIS AREA, ALL ACCESSWAYS HAVE BEEN TIMBERED OFF.