# FALL OF ROOF OR BACK
> MSHA accident `220033390017` · 11/22/2003 · Consol of Kentucky Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** CONSOL Energy Inc
- **Operator:** Consol of Kentucky Inc
- **Mine:** [1518505](https://api.ai-analytics.org/mine/1518505)
## Narrative

AN UNINTENTIONAL ROOF FALL OCCURRED IN THE #3 ENTRY (BELT) STARTING AT BREAK #23 EXTENDING TO BREAK #25, SIZE OF FALL WAS ESTIMATED TO BE 100 - 110' LONG X 10 - 15' HIGH X 18 - 20' WIDE. AREA HAD BEEN SUPPORTED WITH 6' FULLY GROUTED RESIN BOLTS WITH SUPPLEMENTAL SUPPORT CONSISTING OF 10' CABLE BOLTS. NO INJURIES, VENTILATION WAS NOT INTERUPTED, BELT WAS CAUGHT. FALL WON'T BE CLEANE

---