A ROOF FALL WAS FOUND ON 1/2/2004 IN 5LMS MMU 006 IN A 4 WAY INTERSECTION THAT HAD BEEN MINED 12/4/2003 AND WAS SUPPORTED WITH 6' RESIN PINS. FALL WAS 20' X 20' X 10' HIGH. LOCATION WAS ENTRY 1 AT SURVEY STATION 4+80. NO INJURY OR PROPERTY DAMAGE RESULTED.