# HOISTING
> MSHA accident `220040140058` · 01/09/2004 · Monterey Coal Company
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** HOISTING
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Exxon Mobil Corp
- **Operator:** Monterey Coal Company
- **Mine:** [1100726](https://api.ai-analytics.org/mine/1100726)
## Narrative

WHILE INSPECTING THE ELEVATOR, EE TESTED THE EMERGENCY STOP, AND IT FUNCTIONED PROPERLY. WHEN CONTROLS WERE PLACED IN THE NORMAL OPERATION POSITION TO RESUME OPERATION, THE ELEVATOR WOULD NOT MOVE. A CONTACTOR WAS FOUND TO BE MECHANICALLY STUCK IN AND WOULD NOT ALLOW THE ELEVATOR TO MOVE. THE CONTACTOR WAS REPAIRED AND THE ELEVAT0R PLACED BACK INTO SERVICE AT 2:25 PM.

---