A ROOF FALL WAS FOUND IN A 4WAY INTERSECTION AT 8+40 ROOM 3 IN 4RMS MMU 003. THE FALL WAS IN EXAMINER TRAVELWAY IN A SET OF WORKED OUT RETURN ROOMS. THE FALL WAS 20'WIDE X 20'LONG X 10'HIGH. AREA WAS MINED JUNE 15, 2000 & HAD BEEN BOLTED WITH 8'FULL RESIN PINS. NO INJURY OR PROPERTY LOSS RESULTED. THERE ARE NO PLANS TO CLEAN FALL. TRAVELWAY WAS REROUTED.