FALL OF ROOF OR BACK

220040750059 · 03/04/2004 · Anker West Virginia Mining Company Inc

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Anker Group Inc
Operator
Anker West Virginia Mining Company Inc
Mine
4608622

Narrative

WHEN PULLING THE 3RD LIFT OUT OF NO. 6 ENTRY ON I-7 PANEL NEAR SPAD 10096 THE RADIO REMOTE CONTROLLED CONTINUOUS MINER LOST POWER. AFTER APPROX 4 HOURS OF TROUBLESHOOTING THE PROBLEM REPAIRS, WHICH TOOK ANOTHER 2 HOURS, BEGAN. ONCE POWER WAS RESTORED TO THE MACHINE THE PILLARED OUT MINE ROOF HAD SETTLED ONTO THE MACHINE CAUSING IT TO BECOME TRAPPED FOR MORE THAN 1 HOUR.