ROOF FALL #6 ENTRY AT SPAD 2922 ON MAINS SECTION 2 BRK, OUTBY FACE. FALL IS APPROX. 40'LONG BY 40'WIDE GOING THRU INTERSECTION. FALL WAS ABOVE ANCHORAGE FOR THE FALL. BOLTS USED WERE 6'TORQUE TENSION BOLTS WITH 8'CABLE BOLTS. CRIBS HAD BEEN SET TO REDUCE WIDTH OF ENTRY & INTERSECTION.