FALL OF ROOF OR BACK

220040910023 · 03/18/2004 · Rosebud Mining Company

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
J Clifford Forrest III
Operator
Rosebud Mining Company
Mine
3608836

Narrative

A ROOF FALL APPROX 5' HIGH, 18' WIDE, 40' LONG OCCURRED IN THE #3 INTAKE ROOM OF 10+ LEFT BUTT. A CLAY VEIN WAS EVIDENT & THE AREA WAS BOLTED WITH 4' FULLY GROUTED RESIN BOLTS. FALL WAS NOT CLEANED UP SECTION MOVED TO ANOTHER SET OF ROOMS.