A roof fall occurred in the #4 entry face on the 8 left panel (005 section) at #49 crosscut. the fall was approx 40' long x 18' wide x 7' thick and fell outby the pillar line and entrapped two mobile roof supports. 5' high tech bolts had been installed in the area, supplemented with 12' super bolts.