A ROOF FALL WAS FOUND IN A WORKED OUT AREA OF 5R RETURNS ON 5/4/04. THE FALL IN A 4WAY INTERSECTION MEASURED 20'X20'X6' HIGH HAD BEEN SUPPORTED WITH 4' FULLY RESIN PINS. AREA WAS MINED 3/28/04. LIMESTONE SEPARATION ABOVE ANCHORAGE LED TO FAILURE. NO PROPERTY DAMAGE OR INJURY RESULTED. FALL WAS ADJACENT TO EXAMINERS TRAVELWAY. NO PLANS TO CLEA UP