← MSHA accidents

FALL OF ROOF OR BACK

220041380047 · 04/23/2004 · Double A Mining, Inc.

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
O A Stump Jr
Operator
Double A Mining, Inc.
Mine
4407093

Narrative

HIGHWALL AT MOUTH OF DRIFT AT #1 ENTRY. FAN ENTRY FELL DURING IDLE SHIFT. 6' THICK EXTENDING 15' TO INBY DRIFT MOUTH. WE REBUILT CANOPY - CRIBBED ROOF FROM TOP OF CANOPY - INSTALLED HEIZEMAN HEADERS AND JACKS - RELEASED ON 4-30-04.

Source

Authoritative
MSHA Open Government Data
Machine