ROOF FALL WAS DISCOVERED BY AN EMPLOYEE ON 5/1/04 ON #2 SECTION RETURN. THE FALL WAS 30' LONG, 20' WIDE AND APPROX. 7' THICK. THIS MINE IS IDLED. 6' RESIN BOLTS WERE IN USE IN THIS AREA. THERE IS A COAL RIDER SEAM AND WATER PRESENT ABOVE COAL SEAM. THE FALL WILL NOT BE CLEANED UP, BUT WAS DANGERED OFF.