# FALL OF ROOF OR BACK
> MSHA accident `220041600020` · 05/31/2004 · Peabody Midwest Mining, LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Peabody Energy Corporation
- **Operator:** Peabody Midwest Mining, LLC
- **Mine:** [1102971](https://api.ai-analytics.org/mine/1102971)
## Narrative

A ROOF FALL OCCURED IN ENTRY #4 MAIN SOUTH @ SURVEY STATION 31 + 10. THE FALL MEASURED 120' LONG X 19' WIDE X 6' THICK. THE AREA HAD BEEN BOLTED WITH 5' FULLY GROUTED BOLTS. THIS AREA WILL BE CLEANED UP AND REBOLTED.

---