A roof fall in the 1 South x-cut #29 in the #3 entry measuring 35 ft. x 18 ft. x 6 ft. - 9 ft. The area was mined in April 2004 and supported with 6 ft. tension rebar bolts and 9 ft. mega bolts. This fall was caused by a hidden slip in the mine roof.