← MSHA accidents

FALL OF ROOF OR BACK

220041980006 · 07/05/2004 · Road Fork Development Company Inc

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Massey Energy Company
Operator
Road Fork Development Company Inc
Mine
1509830

Narrative

There occurred a roof fall at this mine located at #3 entry inby spad #362 about 2160ft from the working face. It fell on highline cable in the intake. The size of the fall was 20ft L x 20ft W x 6ft H. Conventional 4ft bolts were used and strata was laminate. Ventilation was not affected and there will be no rehab.

Source

Authoritative
MSHA Open Government Data
Machine