UNINTENTIONAL ROOF FALL OCCURRED ON THE 001 SECT. BETWEEN #7 & #8 ENTRY AT #38 CROSSCUT. FALL WAS 25' LONG X 18' WIDE, AND 3' - 6' HIGH. FALL WILL NOT BE CLEANED UP. INITIALLY THE AREA WAS BOLTED WITH 4' FULLY-GROUTED ROOF BOLTS. AREA HAD BEEN DANGERED OFF AND TIMBERED. ROCK HAD BEEN FALLING FROM BETWEEN THE ROOF BOLTS BUT ONLY FOUND TO BE ABOVE THE ANCHOR POINT ON 7/15/04.