← MSHA accidents

FALL OF ROOF OR BACK

220042010108 · 07/15/2004 · Solar Sources Underground L L C

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Felson Bowman
Operator
Solar Sources Underground L L C
Mine
1202103

Narrative

UNINTENTIONAL ROOF FALL OCCURRED ON THE 001 SECT. BETWEEN #7 & #8 ENTRY AT #38 CROSSCUT. FALL WAS 25' LONG X 18' WIDE, AND 3' - 6' HIGH. FALL WILL NOT BE CLEANED UP. INITIALLY THE AREA WAS BOLTED WITH 4' FULLY-GROUTED ROOF BOLTS. AREA HAD BEEN DANGERED OFF AND TIMBERED. ROCK HAD BEEN FALLING FROM BETWEEN THE ROOF BOLTS BUT ONLY FOUND TO BE ABOVE THE ANCHOR POINT ON 7/15/04.

Source

Authoritative
MSHA Open Government Data
Machine